60W-250W Rainproof
MEASUREMENT:232*132*75
Technicalparameters: built-in EMI filter, low output ripple and noise
Protection function: Overload protection/short circuit protection oneyear warranty
AC input voltage range -----------------------176-264VAC
Input frequency -----------------------47-63Hz
Input surge ----------------- Cold start,40A/230VAC
Output voltage adjustment range ---------------±10%
Voltage regulation rate (full load)---------------≤0.5%
Output overload protection--------110%-150% intermittent mode, automatic recovery
Rise time,Hold time ----------50mS,20mS Full load (typical value)
Dielectric strength --------I/P-O/P,I/P-FG:1.5KVAC,,O/P-FG:0.5KVAC,1min
Operating temperature ---------0-40℃@100%,-10%@80%,50℃@60%
Storage environment ------- -20℃~+85℃,20%~95%RH(No frost)
safety standard --------- GB4943,UL60950-1,EN60950-1
EMC standard -------- GB9254,EN55022class A
Cooling method -------Natural convection cooling of air
Product model | DC output | Load regul | R&N | Efficiency |
A-60-12 | 12V,5A | 0.5% | 100mV | 77% |
A-100-12 | 12V,8.4A | 0.5% | 100mV | 81% |
A-120-12 | 12V,10A | 0.5% | 100mV | 81% |
A-150-12 | 12V,12.5A | 0.5% | 100mV | 82% |
A-200-12 | 12V,16.7A | 0.5% | 100mV | 80% |
A-250-12 | 12V,20A | 0.5% | 100mV | 82% |